LC Meter Circuit Coil Capacitor Meter


Posted on Feb 4, 2014

This LC meter circuit can measure coils and capacitors. When Lx or Cx is connected in the circuit the oscillator frequency will decrease and this decrease is measured by a frequency-voltage converter build with T3 and T4. To adjust this lc meter circuit with P1 and P2. LC meter precision is 3%. Scale calibration can be achieved with this formula:


LC Meter Circuit Coil Capacitor Meter
Click here to download the full size of the above Circuit.

ni = nm(1 fr)/(1 fc) where ni is number of divisions measured on the scale, nm = total number of division of the scale, fr = relative frequency, fc = the smallest relative frequency measured.