controller 4017 counter LEDs have multiple connections in this traffic light circuit


Posted on Feb 5, 2014

Why are four legs connected to the green LED and two to the amber LED in the 4017 traffic light circuit Shouldn`t it be able to do with only one leg per LED Each output is consecutively active for the same time. By wired-OR-ing outputs you can create longer active times. So the green LED will be on during 4 time units. Normally you would have to


controller 4017 counter LEDs have multiple connections in this traffic light circuit
Click here to download the full size of the above Circuit.

wired-OR Q0 through Q4 for the red LED, but we have a carry output (here called ":10") which does just that, see the bottom trace of the timing diagram: