Precision-frequency-counter-tachometer


Posted on Jul 13, 2012

In this configuration, the display reads hertz directly. With pin 11 of the ICM7027 A connected to V00, the gating time will be 0.1 second; this will display tens of hertz as the least significant digit.


Precision-frequency-counter-tachometer
Click here to download the full size of the above Circuit.

For shorter gating times, an ICM7207 can be used with a 6.5536-MHz crystal, giving a 0.01 second gating with pin 11 connected to V00, and a 0.1 second gating with pin 11 open.