Dc-voltmeter

  
This de voltmeter, with high input resistance, uses a CA3130 BiMOS op amp and measures voltages from 10 m V to 300 V. Resistors R12 and Rl4 are used individually to calibrate tbe meter for full:scale deflection.
Dc-voltmeter - schematic

Potentiometer R6 is used to null tbe op amp and meter on the 10-mV range by shorting tbe input terminals, then adjusting R6 for tbe first indication of upscale meter deflection.