Electronic Circuits Schematics Projects




Thermocouple to RS-232

Rating: 8.00/10 (14Votes cast)

Category: Meter Counter Circuits / Thermometer Circuits
Views: 4624
Rank: 0

In this circuit, the LT1025 cold-junction compensator provides the signal conditioning. The compensators voltage varies with the temperature of the reference junction in such a way that when summed with the thermocouple voltage, the combination behaves as if the reference junction were maintained at 0°C. (You should place the compensator as close as possible to the reference junction.) The compensator also linearizes the output of the thermocouple and is markedly more convenient than an ice bath.The LTKA00 thermocouple amplifier provides gain adjustment. A two-pole Butterworth filter provides noise reduction and scales the applied signal to the ±5V input range of the SP574 ADC. The circuit adjusts for offset by applying a buffered fraction of visit page.

The LTKA00 thermocouple amplifier provides gain adjustment. A two-pole Butterworth filter provides noise reduction and scales the applied signal to the ±5V input range of the SP574 ADC. The circuit adjusts for offset by applying a buffered fraction of http://www.edn.com/archives/1995/110995/23di2.htm

Related circuits

Soil Heater For Plants Circuit

A TDA1024 electronic thermostat senses soil temperature via thermistor R6. The circuit uses zero-crossing switching of the heater. The heater is made of elastic-coated steel wire. PI is used to set the temperature. The heater should have 2 or more resistance and operate from the 9-V transformer.



Thermometer with a LM335

The circuit consists of two parts: The LM335 and its adjustment. The output of the LM335 is 10 millivolts per degree C, with 25 degrees C corresponding to 2.982 VDC. A reference circuit provides a zero reference voltage. It is adjusted to (2.982 volts - (25 degrees x 10 millivolts/degree) = 2.832...



Temperature-controuer

When power is applied, the thermistor, a negative tc device, is at a high value. A1 saturates positive. This forces the LT3525A switching regulator"s output low, biasing Ql. As the heater warms, the thermistor"s value decreases. When itsinputs finally balance, A1 comes out of saturation and the...



Digital temperature measuring

The output voltage of a thermocouple is converted into frequency measured by a digital frequency meter. The output thermocouple signal is proportional to the temperature difference between the hot junction and the thermostat kept at 0°C, it drives the voltage-to-frequency converter changing...



Digital thermometer

The sensor consists of two series-connected lN914s, part of the circuit of a 555 multivibrator. Wired as shown, the output pulse rate is proportional to the temperature of the diodes



Temperature-reporting-digital-thermometer

The ROMs or PROMs must have the correct code for converting the data from the NE5037 -used as address for the ROMs or PROMs-to the appropriate segment driver codes. The displayed amount could easily be converted to degrees Fahrenheit, °F, by the controller of (0-63 °temperature sensor) or...



Temperature Measurement in a Single Chip

The LTC1392 is designed to be used for PC board temperature and supply voltage/current monitoring or as a remote temperature and voltage sensor for monitoring almost any kind of system. It is available in SO-8 and DIP packages allowing it to fit onto almost any circuit board.



Thermocouple to RS-232

In this circuit, the LT1025 cold-junction compensator provides the signal conditioning. The compensators voltage varies with the temperature of the reference junction in such a way that when summed with the thermocouple voltage, the combination behaves as if the reference junction were maintained...