High Voltage Design Considerations
1. Definition and Importance of High Voltage
Definition and Importance of High Voltage
Fundamental Definition
High voltage (HV) is formally defined by the International Electrotechnical Commission (IEC) as any voltage exceeding 1,000 VAC or 1,500 VDC in low-frequency alternating or direct current systems, respectively. For high-frequency systems (>1 kHz), thresholds scale nonlinearly due to skin effect and dielectric losses. The electric field strength E becomes the critical parameter, governed by:
where V is the electric potential. At high voltages, E approaches the breakdown strength of insulating materials (typically 3–30 kV/mm for solids like polyethylene or alumina).
Physical Significance
High voltage enables:
- Reduced resistive losses: Power transmission at HV (e.g., 400 kV) cuts I²R losses by a factor of 160,000 compared to 100 V systems for equivalent power transfer.
- Electromagnetic field control: HV systems require precise management of corona discharge, governed by Peek's law:
where g0 is the disruptive gradient (≈30 kV/cm in air), δ is air density factor, and d/r is the conductor-to-ground geometry ratio.
Engineering Imperatives
HV design demands:
- Partial discharge management: Localized dielectric breakdowns must be kept below 5 pC for reliable operation.
- Creepage and clearance: IEC 60664-1 specifies minimum distances (e.g., 25 mm/kV for pollution degree 2).
- Transient protection: Lightning impulses (1.2/50 μs waveshape) require clamping within 10% of rated voltage.
Historical Context
The 1891 Lauffen-Frankfurt demonstration established 25 kV AC transmission, proving HV's efficiency over Edison's DC systems. Modern ultra-high voltage (UHV) lines in China operate at 1,100 kV, achieving 3,000 km transmission with <5% losses.
Applications
Critical HV applications include:
- Particle accelerators: 50 MV electrostatic generators for nuclear research.
- Medical imaging: 150 kVp X-ray tubes with <0.1% ripple.
- Industrial processes: 100 kV electrostatic precipitators for emission control.
1.2 Key Physical Principles in High Voltage Design
Electric Field Distribution and Breakdown Mechanisms
The electric field E in a high-voltage system is governed by Poisson's equation, which relates the potential distribution V to the charge density ρ and permittivity ε:
In homogeneous materials, the electric field is uniform, but in practical systems, inhomogeneities (e.g., sharp edges, voids, or insulating interfaces) lead to field enhancement. The critical field strength Ec at which breakdown occurs depends on the medium:
- Air: ~3 kV/mm at standard temperature and pressure (Paschen’s law governs breakdown).
- Oil: ~10–20 kV/mm (highly dependent on purity and moisture content).
- Solid dielectrics: ~20–100 kV/mm (varies with material and defects).
Paschen’s Law and Gas Breakdown
For gaseous dielectrics, breakdown voltage Vb is a function of the product of pressure p and gap distance d:
where A and B are gas-dependent constants, and γ is the secondary electron emission coefficient. The curve exhibits a minimum, implying an optimal pd for minimal breakdown voltage.
Corona Discharge and Partial Discharge
At high fields, localized ionization (corona) occurs before full breakdown. The onset field Ecorona for a cylindrical conductor of radius r is approximated by Peek’s empirical formula:
where m is the surface roughness factor (~0.6–1.0) and δ is the relative air density. Partial discharge (PD) in solid dielectrics follows similar principles but is influenced by cavity size and dielectric constant mismatch.
Thermal Effects and Dielectric Losses
High-voltage systems generate heat due to dielectric losses, quantified by the loss tangent tan δ:
where f is frequency, ϵr is relative permittivity, and E is the electric field. Excessive heating accelerates aging and reduces insulation lifetime.
Surface Flashover and Creepage
Flashover along insulating surfaces depends on creepage distance, defined by IEC standards. The required creepage distance dc for a given voltage V and pollution severity is:
where k is a material constant and CPI is the contamination performance index. Practical designs use ribbed or grooved surfaces to increase effective creepage.
Practical Implications
- Grading rings redistribute electric fields to avoid localized stress.
- SF6 gas is used in switchgear due to its high dielectric strength (3× air) and self-healing properties.
- Nanocomposite dielectrics enhance breakdown strength by trapping charge carriers at interfaces.
1.3 Common Applications of High Voltage Systems
Power Transmission and Distribution
High voltage (HV) systems dominate modern power grids due to their efficiency in reducing resistive losses over long distances. The power loss Ploss in a transmission line is given by:
where I is the current and R is the line resistance. By stepping up voltage using transformers, current is reduced quadratically for the same power transfer, making HV transmission (typically 115 kV to 765 kV) indispensable. Ultra-high-voltage (UHV) lines (>800 kV) further minimize losses in continental-scale grids.
Medical Imaging and Radiation Therapy
X-ray tubes and linear accelerators (LINACs) rely on potentials ranging from 50 kV to 25 MV. The kinetic energy of electrons accelerated through voltage V is:
where e is the electron charge. In computed tomography (CT), rotating anode X-ray tubes operate at 80-140 kV, while radiotherapy LINACs use pulsed RF fields to achieve multi-MeV energies for tumor targeting.
Industrial Processes
- Electrostatic precipitators: Employ 50-100 kV DC to remove particulate matter from flue gases via corona discharge.
- Plasma etching: Semiconductor fabrication uses 1-5 kV RF plasmas for nanoscale patterning.
- Pulsed power systems: Capacitor banks charged to 100 kV+ deliver megawatt pulses for electromagnetic forming.
Scientific Research
Particle accelerators like the Large Hadron Collider (LHC) utilize superconducting RF cavities at 2-20 MV/m gradients. The achievable beam energy scales as:
where Vi are the accelerating voltages across N stages and q is particle charge. High-voltage pulse generators also drive Z-pinch and laser plasma experiments.
Electrical Insulation Testing
Dielectric withstand tests apply 2-300 kV AC/DC to verify insulation integrity. The breakdown field strength Ebd follows:
where d is insulation thickness. Partial discharge detection at HV helps predict insulation failure in transformers and cables.
High-Energy Physics Detectors
Photomultiplier tubes (PMTs) and drift chambers require 1-5 kV supplies. The electron multiplication gain G in a PMT dynode chain is:
where δ is secondary emission yield (~3-6 per stage) and n is the number of dynodes. Time projection chambers (TPCs) use uniform HV fields (1-10 kV/cm) for charged particle tracking.
1.3 Common Applications of High Voltage Systems
Power Transmission and Distribution
High voltage (HV) systems dominate modern power grids due to their efficiency in reducing resistive losses over long distances. The power loss Ploss in a transmission line is given by:
where I is the current and R is the line resistance. By stepping up voltage using transformers, current is reduced quadratically for the same power transfer, making HV transmission (typically 115 kV to 765 kV) indispensable. Ultra-high-voltage (UHV) lines (>800 kV) further minimize losses in continental-scale grids.
Medical Imaging and Radiation Therapy
X-ray tubes and linear accelerators (LINACs) rely on potentials ranging from 50 kV to 25 MV. The kinetic energy of electrons accelerated through voltage V is:
where e is the electron charge. In computed tomography (CT), rotating anode X-ray tubes operate at 80-140 kV, while radiotherapy LINACs use pulsed RF fields to achieve multi-MeV energies for tumor targeting.
Industrial Processes
- Electrostatic precipitators: Employ 50-100 kV DC to remove particulate matter from flue gases via corona discharge.
- Plasma etching: Semiconductor fabrication uses 1-5 kV RF plasmas for nanoscale patterning.
- Pulsed power systems: Capacitor banks charged to 100 kV+ deliver megawatt pulses for electromagnetic forming.
Scientific Research
Particle accelerators like the Large Hadron Collider (LHC) utilize superconducting RF cavities at 2-20 MV/m gradients. The achievable beam energy scales as:
where Vi are the accelerating voltages across N stages and q is particle charge. High-voltage pulse generators also drive Z-pinch and laser plasma experiments.
Electrical Insulation Testing
Dielectric withstand tests apply 2-300 kV AC/DC to verify insulation integrity. The breakdown field strength Ebd follows:
where d is insulation thickness. Partial discharge detection at HV helps predict insulation failure in transformers and cables.
High-Energy Physics Detectors
Photomultiplier tubes (PMTs) and drift chambers require 1-5 kV supplies. The electron multiplication gain G in a PMT dynode chain is:
where δ is secondary emission yield (~3-6 per stage) and n is the number of dynodes. Time projection chambers (TPCs) use uniform HV fields (1-10 kV/cm) for charged particle tracking.
2. Insulation Materials and Their Properties
2.1 Insulation Materials and Their Properties
The selection of insulation materials in high-voltage systems is governed by their dielectric strength, thermal stability, mechanical robustness, and environmental resistance. The dielectric strength, defined as the maximum electric field a material can withstand before breakdown, is a critical parameter:
where \( E_{breakdown} \) is the dielectric strength (V/m), \( V_{breakdown} \) is the breakdown voltage (V), and \( d \) is the thickness (m). This linear relationship holds for uniform fields but becomes nonlinear in divergent field geometries, necessitating empirical corrections.
Key Material Classes
Solid Insulators: Common materials include cross-linked polyethylene (XLPE), epoxy resins, and porcelain. XLPE exhibits a dielectric strength of ~20–30 kV/mm and is widely used in power cables due to its flexibility and moisture resistance. Epoxy resins, with strengths up to 40 kV/mm, are preferred for encapsulating high-voltage components. Porcelain, though brittle, offers excellent surface tracking resistance and is used in outdoor insulators.
Liquid Insulators: Mineral oil and silicone fluids dominate. Mineral oil’s dielectric strength (~12–15 kV/mm) degrades with moisture absorption, while silicone fluids maintain stability up to 200°C. Synthetic esters are emerging as eco-friendly alternatives with comparable performance.
Gaseous Insulators: SF₆ is the gold standard for gas-insulated switchgear (GIS), with a dielectric strength ~3× that of air at 0.1 MPa. However, its high global warming potential (GWP) has spurred research into alternatives like CF₃I mixtures and compressed air.
Material Selection Criteria
- Partial Discharge Inception Voltage (PDIV): Must exceed operating voltages to prevent cumulative damage. For polymers, PDIV correlates with material purity and void content.
- Thermal Class: Defined by IEC 60085 (e.g., Class B = 130°C, Class F = 155°C). Higher classes enable compact designs but may compromise mechanical properties.
- Tracking Resistance: Measured via the Comparative Tracking Index (CTI). Materials with CTI ≥ 600 are deemed high-tracking-resistant.
Case Study: Insulation in Power Transformers
Transformer insulation combines oil (cooling/insulation) and cellulose paper (solid insulation). The aging rate of cellulose follows Arrhenius kinetics:
where \( k \) is the degradation rate, \( E_a \) is activation energy (~111 kJ/mol for cellulose), and \( T \) is temperature (K). Moisture reduces \( E_a \), accelerating aging—hence the need for oil filtration systems.
Emerging Materials
Nanocomposites (e.g., epoxy/SiO₂) show enhanced dielectric strength (>50 kV/mm) due to interfacial polarization effects. High-entropy ceramics are being explored for ultra-high-temperature applications (>1000°C).
2.1 Insulation Materials and Their Properties
The selection of insulation materials in high-voltage systems is governed by their dielectric strength, thermal stability, mechanical robustness, and environmental resistance. The dielectric strength, defined as the maximum electric field a material can withstand before breakdown, is a critical parameter:
where \( E_{breakdown} \) is the dielectric strength (V/m), \( V_{breakdown} \) is the breakdown voltage (V), and \( d \) is the thickness (m). This linear relationship holds for uniform fields but becomes nonlinear in divergent field geometries, necessitating empirical corrections.
Key Material Classes
Solid Insulators: Common materials include cross-linked polyethylene (XLPE), epoxy resins, and porcelain. XLPE exhibits a dielectric strength of ~20–30 kV/mm and is widely used in power cables due to its flexibility and moisture resistance. Epoxy resins, with strengths up to 40 kV/mm, are preferred for encapsulating high-voltage components. Porcelain, though brittle, offers excellent surface tracking resistance and is used in outdoor insulators.
Liquid Insulators: Mineral oil and silicone fluids dominate. Mineral oil’s dielectric strength (~12–15 kV/mm) degrades with moisture absorption, while silicone fluids maintain stability up to 200°C. Synthetic esters are emerging as eco-friendly alternatives with comparable performance.
Gaseous Insulators: SF₆ is the gold standard for gas-insulated switchgear (GIS), with a dielectric strength ~3× that of air at 0.1 MPa. However, its high global warming potential (GWP) has spurred research into alternatives like CF₃I mixtures and compressed air.
Material Selection Criteria
- Partial Discharge Inception Voltage (PDIV): Must exceed operating voltages to prevent cumulative damage. For polymers, PDIV correlates with material purity and void content.
- Thermal Class: Defined by IEC 60085 (e.g., Class B = 130°C, Class F = 155°C). Higher classes enable compact designs but may compromise mechanical properties.
- Tracking Resistance: Measured via the Comparative Tracking Index (CTI). Materials with CTI ≥ 600 are deemed high-tracking-resistant.
Case Study: Insulation in Power Transformers
Transformer insulation combines oil (cooling/insulation) and cellulose paper (solid insulation). The aging rate of cellulose follows Arrhenius kinetics:
where \( k \) is the degradation rate, \( E_a \) is activation energy (~111 kJ/mol for cellulose), and \( T \) is temperature (K). Moisture reduces \( E_a \), accelerating aging—hence the need for oil filtration systems.
Emerging Materials
Nanocomposites (e.g., epoxy/SiO₂) show enhanced dielectric strength (>50 kV/mm) due to interfacial polarization effects. High-entropy ceramics are being explored for ultra-high-temperature applications (>1000°C).
2.2 Breakdown Mechanisms and Voltage Stress
Fundamental Breakdown Phenomena
Electrical breakdown occurs when an insulating material transitions from a high-resistance state to a conductive path due to excessive electric field stress. The threshold is characterized by the breakdown field strength (Ebd), material-dependent and typically expressed in kV/mm. Two primary mechanisms dominate:
- Avalanche Breakdown: Occurs when free carriers gain sufficient energy to ionize lattice atoms, creating electron-hole pairs that multiply exponentially.
- Thermal Breakdown: Results from Joule heating exceeding the material's thermal dissipation capacity, leading to runaway temperature rise.
where Vbd is the breakdown voltage and d is the insulation thickness. For air at STP, Ebd ≈ 3 kV/mm, while alumina ceramics exceed 10 kV/mm.
Field Enhancement and Geometric Effects
Local electric field intensification at sharp edges or voids often precipitates premature breakdown. The field enhancement factor (β) quantifies this effect:
For a hemispherical protrusion of radius r on a plane electrode, β ≈ 3. Practical designs employ Rogowski or Bruce profiles to limit β < 1.5.
Partial Discharge and Aging
Under AC or pulsed DC, incomplete discharges in microscopic voids generate reactive species that erode insulation. The partial discharge inception voltage (PDIV) follows:
where Evoid is the void's internal field, tvoid its thickness, and εr the relative permittivity. PD activity accelerates insulation aging through chemical degradation and surface tracking.
Time-Dependent Breakdown
Breakdown voltage exhibits temporal dependence governed by the inverse power law for polymers:
where tf is time-to-failure, E the applied field, and n the voltage endurance coefficient (typically 9-12 for epoxy). This model informs lifetime predictions in rotating machine insulation.
Practical Mitigation Strategies
- Grading electrodes to equalize potential distribution
- Embedded shielding to divert surface currents
- Nanocomposite dielectrics to increase intrinsic Ebd
2.2 Breakdown Mechanisms and Voltage Stress
Fundamental Breakdown Phenomena
Electrical breakdown occurs when an insulating material transitions from a high-resistance state to a conductive path due to excessive electric field stress. The threshold is characterized by the breakdown field strength (Ebd), material-dependent and typically expressed in kV/mm. Two primary mechanisms dominate:
- Avalanche Breakdown: Occurs when free carriers gain sufficient energy to ionize lattice atoms, creating electron-hole pairs that multiply exponentially.
- Thermal Breakdown: Results from Joule heating exceeding the material's thermal dissipation capacity, leading to runaway temperature rise.
where Vbd is the breakdown voltage and d is the insulation thickness. For air at STP, Ebd ≈ 3 kV/mm, while alumina ceramics exceed 10 kV/mm.
Field Enhancement and Geometric Effects
Local electric field intensification at sharp edges or voids often precipitates premature breakdown. The field enhancement factor (β) quantifies this effect:
For a hemispherical protrusion of radius r on a plane electrode, β ≈ 3. Practical designs employ Rogowski or Bruce profiles to limit β < 1.5.
Partial Discharge and Aging
Under AC or pulsed DC, incomplete discharges in microscopic voids generate reactive species that erode insulation. The partial discharge inception voltage (PDIV) follows:
where Evoid is the void's internal field, tvoid its thickness, and εr the relative permittivity. PD activity accelerates insulation aging through chemical degradation and surface tracking.
Time-Dependent Breakdown
Breakdown voltage exhibits temporal dependence governed by the inverse power law for polymers:
where tf is time-to-failure, E the applied field, and n the voltage endurance coefficient (typically 9-12 for epoxy). This model informs lifetime predictions in rotating machine insulation.
Practical Mitigation Strategies
- Grading electrodes to equalize potential distribution
- Embedded shielding to divert surface currents
- Nanocomposite dielectrics to increase intrinsic Ebd
2.3 Design Considerations for Insulation Systems
Electric Field Stress and Dielectric Strength
The primary challenge in high-voltage insulation design is managing electric field stress to prevent dielectric breakdown. The electric field E in a uniform gap is given by:
where V is the applied voltage and d is the distance between electrodes. However, real-world geometries often exhibit non-uniform fields, requiring numerical methods like finite element analysis (FEA) for accurate modeling. The dielectric strength Eb of common materials ranges from 3 kV/mm for air to 20 kV/mm for polyethylene under standard conditions.
Material Selection Criteria
Insulation materials must satisfy multiple constraints:
- Thermal stability: High-temperature operation without degradation
- Mechanical robustness: Resistance to vibration and thermal cycling
- Chemical inertness: Immunity to oxidation and moisture absorption
- Partial discharge resistance: Withstand localized ionization events
Modern composite materials like epoxy-SiC nano-composites achieve dielectric strengths exceeding 30 kV/mm while maintaining thermal conductivity >1 W/mK.
Creepage and Clearance Distances
Surface discharge phenomena necessitate careful dimensioning of creepage paths. The minimum creepage distance Lc follows:
where kv is a material-dependent constant (0.5-2.5 mm/kV for most polymers). IEC 60664-1 provides standardized pollution degree classifications that modify these requirements based on environmental contamination levels.
Partial Discharge Inception Voltage (PDIV)
The PDIV marks the onset of localized breakdown in microscopic voids:
where r is the void radius, d0 the void height, and εr the relative permittivity. Modern insulation systems employ PDIV enhancement techniques such as:
- Gas pressure elevation (SF6 or N2 mixtures)
- Surface fluorination for polymer modification
- Embedded conductive layers for field grading
Thermal-Electrical Coupling Effects
The Arrhenius relationship governs thermal aging:
where Ea is the activation energy (0.8-1.2 eV for cellulose), k Boltzmann's constant, and T absolute temperature. This creates a feedback loop where increased temperature reduces insulation lifetime, leading to higher leakage currents and further heating.
Multiphysics Simulation Approaches
Modern design workflows integrate coupled simulations:
- Electrostatic analysis for field distribution
- Thermal modeling for heat generation and transfer
- Mechanical stress analysis for deformation effects
- Partial discharge propagation modeling
Commercial tools like COMSOL Multiphysics implement this through successive approximation methods, typically requiring mesh resolutions below 100 μm for accurate void modeling.
2.3 Design Considerations for Insulation Systems
Electric Field Stress and Dielectric Strength
The primary challenge in high-voltage insulation design is managing electric field stress to prevent dielectric breakdown. The electric field E in a uniform gap is given by:
where V is the applied voltage and d is the distance between electrodes. However, real-world geometries often exhibit non-uniform fields, requiring numerical methods like finite element analysis (FEA) for accurate modeling. The dielectric strength Eb of common materials ranges from 3 kV/mm for air to 20 kV/mm for polyethylene under standard conditions.
Material Selection Criteria
Insulation materials must satisfy multiple constraints:
- Thermal stability: High-temperature operation without degradation
- Mechanical robustness: Resistance to vibration and thermal cycling
- Chemical inertness: Immunity to oxidation and moisture absorption
- Partial discharge resistance: Withstand localized ionization events
Modern composite materials like epoxy-SiC nano-composites achieve dielectric strengths exceeding 30 kV/mm while maintaining thermal conductivity >1 W/mK.
Creepage and Clearance Distances
Surface discharge phenomena necessitate careful dimensioning of creepage paths. The minimum creepage distance Lc follows:
where kv is a material-dependent constant (0.5-2.5 mm/kV for most polymers). IEC 60664-1 provides standardized pollution degree classifications that modify these requirements based on environmental contamination levels.
Partial Discharge Inception Voltage (PDIV)
The PDIV marks the onset of localized breakdown in microscopic voids:
where r is the void radius, d0 the void height, and εr the relative permittivity. Modern insulation systems employ PDIV enhancement techniques such as:
- Gas pressure elevation (SF6 or N2 mixtures)
- Surface fluorination for polymer modification
- Embedded conductive layers for field grading
Thermal-Electrical Coupling Effects
The Arrhenius relationship governs thermal aging:
where Ea is the activation energy (0.8-1.2 eV for cellulose), k Boltzmann's constant, and T absolute temperature. This creates a feedback loop where increased temperature reduces insulation lifetime, leading to higher leakage currents and further heating.
Multiphysics Simulation Approaches
Modern design workflows integrate coupled simulations:
- Electrostatic analysis for field distribution
- Thermal modeling for heat generation and transfer
- Mechanical stress analysis for deformation effects
- Partial discharge propagation modeling
Commercial tools like COMSOL Multiphysics implement this through successive approximation methods, typically requiring mesh resolutions below 100 μm for accurate void modeling.
3. Hazards Associated with High Voltage
3.1 Hazards Associated with High Voltage
Electrical Breakdown and Arcing
High voltage systems are susceptible to electrical breakdown, where insulating materials fail and allow current to flow unexpectedly. The breakdown voltage depends on the material's dielectric strength, governed by Paschen's Law for gases:
where Vb is the breakdown voltage, p is gas pressure, d is gap distance, and A, B, γ are material constants. In solids, partial discharges (corona) degrade insulation over time, leading to catastrophic failure.
Shock and Electrocution Risks
Human body impedance (≈1 kΩ for wet skin) allows lethal currents at high voltages. The let-go threshold (10-30 mA) is exceeded by:
At 1 kV, even through dry skin (≈100 kΩ), current exceeds 10 mA. Arc flash incidents generate temperatures >20,000°C, causing severe burns and blast trauma.
Electromagnetic Interference (EMI)
Fast-switching high voltage circuits produce broadband EMI via:
- Radiated emissions from ∂I/∂t in conductors
- Conducted noise through power/ground loops
- Coupling to adjacent circuits via parasitic capacitance
The spectral density of switching noise follows:
Material Degradation
High electric fields (>3 kV/mm) induce:
- Electrochemical migration: Metal ion transport across insulators
- Treeing: Dendritic growth in polymers
- Partial discharge erosion: Pitting in ceramic dielectrics
The time-to-failure follows an inverse power law:
where E is field strength and n ranges from 3-12 for common dielectrics.
Mitigation Strategies
Effective countermeasures include:
- Creepage/clearance distances per IEC 60664-1
- Guard rings to control field gradients
- SF6 or vacuum insulation for arc suppression
- Shielded enclosures with proper grounding
3.1 Hazards Associated with High Voltage
Electrical Breakdown and Arcing
High voltage systems are susceptible to electrical breakdown, where insulating materials fail and allow current to flow unexpectedly. The breakdown voltage depends on the material's dielectric strength, governed by Paschen's Law for gases:
where Vb is the breakdown voltage, p is gas pressure, d is gap distance, and A, B, γ are material constants. In solids, partial discharges (corona) degrade insulation over time, leading to catastrophic failure.
Shock and Electrocution Risks
Human body impedance (≈1 kΩ for wet skin) allows lethal currents at high voltages. The let-go threshold (10-30 mA) is exceeded by:
At 1 kV, even through dry skin (≈100 kΩ), current exceeds 10 mA. Arc flash incidents generate temperatures >20,000°C, causing severe burns and blast trauma.
Electromagnetic Interference (EMI)
Fast-switching high voltage circuits produce broadband EMI via:
- Radiated emissions from ∂I/∂t in conductors
- Conducted noise through power/ground loops
- Coupling to adjacent circuits via parasitic capacitance
The spectral density of switching noise follows:
Material Degradation
High electric fields (>3 kV/mm) induce:
- Electrochemical migration: Metal ion transport across insulators
- Treeing: Dendritic growth in polymers
- Partial discharge erosion: Pitting in ceramic dielectrics
The time-to-failure follows an inverse power law:
where E is field strength and n ranges from 3-12 for common dielectrics.
Mitigation Strategies
Effective countermeasures include:
- Creepage/clearance distances per IEC 60664-1
- Guard rings to control field gradients
- SF6 or vacuum insulation for arc suppression
- Shielded enclosures with proper grounding
3.2 Protective Devices and Techniques
Surge Arresters and Spark Gaps
Surge arresters are critical for diverting transient overvoltages away from sensitive equipment. A gas discharge tube (GDT) or metal-oxide varistor (MOV) clamps voltage spikes by transitioning from a high-impedance to a low-impedance state when the threshold voltage is exceeded. The breakdown voltage VBR of a spark gap is determined by Paschen's law:
where p is gas pressure, d is gap distance, and A, B, γ are material constants. For air at STP, A ≈ 112.50 (kPa·cm)−1 and B ≈ 2737.50 V/(kPa·cm).
Crowbar Circuits and Current Limiting
Thyristor-based crowbar circuits provide rapid short-circuiting during overvoltage events. The triggering delay td must be shorter than the insulation withstand time:
where W is the dielectric energy absorption limit and P is the incident power. Current limiting employs:
- Positive temperature coefficient (PTC) thermistors for self-resetting protection
- Fast-acting fuses with I2t ratings matched to protected components
- Active current mirrors in semiconductor-based limiters
Insulation Coordination
The protective margin M between withstand voltage Vw and protective level Vp follows:
IEEE Std 1313.2 recommends M ≥ 0.15 for equipment up to 245 kV. Creepage distance dc for polluted environments is calculated per IEC 60815:
where k is pollution severity factor (1.0–2.2) and ρ is surface resistivity.
Active Voltage Clamping
Silicon carbide (SiC) transient voltage suppressors offer nanosecond response with clamping ratios Cr = Vclamp/VBR below 1.5. The energy absorption capability E scales with volume:
where Cj is junction capacitance. For multi-stage protection, stagger-tuned LC filters suppress specific frequency bands:
Grounding Strategies
Counterpoise grids reduce step potential during faults. The ground potential rise GPR is:
where Ig is fault current and Rg is grid resistance. For hemispherical electrodes, Rg ≈ ρ/(2πr), where r is electrode radius.
3.2 Protective Devices and Techniques
Surge Arresters and Spark Gaps
Surge arresters are critical for diverting transient overvoltages away from sensitive equipment. A gas discharge tube (GDT) or metal-oxide varistor (MOV) clamps voltage spikes by transitioning from a high-impedance to a low-impedance state when the threshold voltage is exceeded. The breakdown voltage VBR of a spark gap is determined by Paschen's law:
where p is gas pressure, d is gap distance, and A, B, γ are material constants. For air at STP, A ≈ 112.50 (kPa·cm)−1 and B ≈ 2737.50 V/(kPa·cm).
Crowbar Circuits and Current Limiting
Thyristor-based crowbar circuits provide rapid short-circuiting during overvoltage events. The triggering delay td must be shorter than the insulation withstand time:
where W is the dielectric energy absorption limit and P is the incident power. Current limiting employs:
- Positive temperature coefficient (PTC) thermistors for self-resetting protection
- Fast-acting fuses with I2t ratings matched to protected components
- Active current mirrors in semiconductor-based limiters
Insulation Coordination
The protective margin M between withstand voltage Vw and protective level Vp follows:
IEEE Std 1313.2 recommends M ≥ 0.15 for equipment up to 245 kV. Creepage distance dc for polluted environments is calculated per IEC 60815:
where k is pollution severity factor (1.0–2.2) and ρ is surface resistivity.
Active Voltage Clamping
Silicon carbide (SiC) transient voltage suppressors offer nanosecond response with clamping ratios Cr = Vclamp/VBR below 1.5. The energy absorption capability E scales with volume:
where Cj is junction capacitance. For multi-stage protection, stagger-tuned LC filters suppress specific frequency bands:
Grounding Strategies
Counterpoise grids reduce step potential during faults. The ground potential rise GPR is:
where Ig is fault current and Rg is grid resistance. For hemispherical electrodes, Rg ≈ ρ/(2πr), where r is electrode radius.
Standards and Regulations for High Voltage Safety
International Electrotechnical Commission (IEC) Standards
The IEC 60038 standard defines voltage bands for electrical systems, with high voltage typically classified as exceeding 1000 V AC or 1500 V DC. IEC 61936-1 provides requirements for the design and installation of high voltage systems above 1 kV AC and 1.5 kV DC, covering:
- Clearance and creepage distances
- Insulation coordination
- Protection against electric shock
- Equipment marking and labeling
For insulation testing, IEC 60243 specifies test methods for solid insulating materials, with the breakdown voltage Vbd given by:
where Ebd is the dielectric strength (kV/mm) and d is the insulation thickness (mm).
IEEE Standards for High Voltage Systems
IEEE C2 (National Electrical Safety Code) establishes safety standards for installation, operation, and maintenance of high voltage systems. Key requirements include:
- Minimum approach distances based on voltage level
- Grounding and bonding practices
- Overcurrent protection coordination
IEEE 516 provides guidelines for live working, specifying the minimum approach distance D as:
where kV is the system voltage and M is the margin factor (typically 0.61 m for voltages above 72.5 kV).
Regional and National Regulations
In the United States, OSHA 29 CFR 1910.269 regulates work practices for high voltage systems, while NFPA 70E addresses electrical safety in the workplace. The European Union implements these requirements through EN 50110 for operation of electrical installations.
For clearance distances in air, the IEC 60071-2 standard provides the following empirical formula for withstand voltage V50:
where k is a correction factor (1.0 for standard conditions) and d is the gap distance in meters.
Safety Testing and Certification
High voltage equipment must undergo rigorous testing per IEC 62271 for switchgear, IEC 60076 for transformers, and IEC 61439 for assemblies. Key tests include:
- Dielectric withstand (power frequency and impulse)
- Partial discharge measurement
- Temperature rise verification
- Short-circuit withstand capability
The dielectric test voltage Vtest is typically calculated as:
where Um is the maximum system voltage.
Standards and Regulations for High Voltage Safety
International Electrotechnical Commission (IEC) Standards
The IEC 60038 standard defines voltage bands for electrical systems, with high voltage typically classified as exceeding 1000 V AC or 1500 V DC. IEC 61936-1 provides requirements for the design and installation of high voltage systems above 1 kV AC and 1.5 kV DC, covering:
- Clearance and creepage distances
- Insulation coordination
- Protection against electric shock
- Equipment marking and labeling
For insulation testing, IEC 60243 specifies test methods for solid insulating materials, with the breakdown voltage Vbd given by:
where Ebd is the dielectric strength (kV/mm) and d is the insulation thickness (mm).
IEEE Standards for High Voltage Systems
IEEE C2 (National Electrical Safety Code) establishes safety standards for installation, operation, and maintenance of high voltage systems. Key requirements include:
- Minimum approach distances based on voltage level
- Grounding and bonding practices
- Overcurrent protection coordination
IEEE 516 provides guidelines for live working, specifying the minimum approach distance D as:
where kV is the system voltage and M is the margin factor (typically 0.61 m for voltages above 72.5 kV).
Regional and National Regulations
In the United States, OSHA 29 CFR 1910.269 regulates work practices for high voltage systems, while NFPA 70E addresses electrical safety in the workplace. The European Union implements these requirements through EN 50110 for operation of electrical installations.
For clearance distances in air, the IEC 60071-2 standard provides the following empirical formula for withstand voltage V50:
where k is a correction factor (1.0 for standard conditions) and d is the gap distance in meters.
Safety Testing and Certification
High voltage equipment must undergo rigorous testing per IEC 62271 for switchgear, IEC 60076 for transformers, and IEC 61439 for assemblies. Key tests include:
- Dielectric withstand (power frequency and impulse)
- Partial discharge measurement
- Temperature rise verification
- Short-circuit withstand capability
The dielectric test voltage Vtest is typically calculated as:
where Um is the maximum system voltage.
4. Transformers and High Voltage Power Supplies
4.1 Transformers and High Voltage Power Supplies
Transformer Fundamentals
The transformer is the cornerstone of high voltage power supply design, enabling efficient voltage conversion through electromagnetic induction. The primary-secondary voltage relationship is governed by Faraday's law of induction and the turns ratio:
where Vp and Vs are the primary and secondary voltages, and Np and Ns are the respective winding turns. For high voltage applications, the secondary winding typically employs finer gauge wire with significantly more turns than the primary.
High Voltage Transformer Design
Key considerations for HV transformer design include:
- Insulation breakdown: Inter-layer and inter-winding insulation must withstand peak voltages plus safety margins
- Leakage inductance: Minimized through careful winding techniques like interleaving or sectional coils
- Core saturation: High permeability materials with appropriate cross-sectional area prevent saturation at design currents
- Dielectric losses: High frequency designs require low-loss insulation materials like PTFE or polyimide
The maximum output voltage is constrained by the insulation system's dielectric strength, typically expressed in kV/mm. For oil-immersed transformers, this ranges from 10-20 kV/mm, while dry-type designs may be limited to 3-5 kV/mm.
Voltage Multiplication Circuits
When transformer output requires further amplification, voltage multiplier topologies are employed:
for an n-stage Cockcroft-Walton multiplier, where Vpeak is the input AC peak voltage. The ripple voltage ΔV is given by:
where Iload is the output current, f is the input frequency, and C is the stage capacitance. Practical implementations must balance size constraints against ripple requirements.
Regulation and Stability
High voltage regulation presents unique challenges due to:
- Parasitic capacitance effects (typically 10-100 pF/cm in winding structures)
- Temperature-dependent insulation resistance
- Corona discharge at sharp edges exceeding 3 kV/mm in air
Feedback regulation often employs resistive dividers with guard rings to prevent surface leakage. The regulation percentage is calculated as:
Practical Implementation
Modern HV power supplies frequently combine resonant converter topologies with soft-switching techniques to achieve efficiencies exceeding 90%. A typical design sequence involves:
- Determining required output specifications (voltage, current, ripple)
- Selecting appropriate core material (nanocrystalline alloys for >20 kHz operation)
- Calculating winding parameters considering skin and proximity effects
- Designing insulation systems with proper creepage and clearance distances
For medical or industrial X-ray systems operating at 50-150 kV, oil-filled or gas-insulated designs are common, while particle accelerators may employ cascaded rectifier systems for MV-range outputs.
4.1 Transformers and High Voltage Power Supplies
Transformer Fundamentals
The transformer is the cornerstone of high voltage power supply design, enabling efficient voltage conversion through electromagnetic induction. The primary-secondary voltage relationship is governed by Faraday's law of induction and the turns ratio:
where Vp and Vs are the primary and secondary voltages, and Np and Ns are the respective winding turns. For high voltage applications, the secondary winding typically employs finer gauge wire with significantly more turns than the primary.
High Voltage Transformer Design
Key considerations for HV transformer design include:
- Insulation breakdown: Inter-layer and inter-winding insulation must withstand peak voltages plus safety margins
- Leakage inductance: Minimized through careful winding techniques like interleaving or sectional coils
- Core saturation: High permeability materials with appropriate cross-sectional area prevent saturation at design currents
- Dielectric losses: High frequency designs require low-loss insulation materials like PTFE or polyimide
The maximum output voltage is constrained by the insulation system's dielectric strength, typically expressed in kV/mm. For oil-immersed transformers, this ranges from 10-20 kV/mm, while dry-type designs may be limited to 3-5 kV/mm.
Voltage Multiplication Circuits
When transformer output requires further amplification, voltage multiplier topologies are employed:
for an n-stage Cockcroft-Walton multiplier, where Vpeak is the input AC peak voltage. The ripple voltage ΔV is given by:
where Iload is the output current, f is the input frequency, and C is the stage capacitance. Practical implementations must balance size constraints against ripple requirements.
Regulation and Stability
High voltage regulation presents unique challenges due to:
- Parasitic capacitance effects (typically 10-100 pF/cm in winding structures)
- Temperature-dependent insulation resistance
- Corona discharge at sharp edges exceeding 3 kV/mm in air
Feedback regulation often employs resistive dividers with guard rings to prevent surface leakage. The regulation percentage is calculated as:
Practical Implementation
Modern HV power supplies frequently combine resonant converter topologies with soft-switching techniques to achieve efficiencies exceeding 90%. A typical design sequence involves:
- Determining required output specifications (voltage, current, ripple)
- Selecting appropriate core material (nanocrystalline alloys for >20 kHz operation)
- Calculating winding parameters considering skin and proximity effects
- Designing insulation systems with proper creepage and clearance distances
For medical or industrial X-ray systems operating at 50-150 kV, oil-filled or gas-insulated designs are common, while particle accelerators may employ cascaded rectifier systems for MV-range outputs.
4.2 Capacitors and Inductors in High Voltage Circuits
Capacitor Selection and Voltage Stress
In high-voltage circuits, capacitors must withstand significant electric fields without dielectric breakdown. The voltage rating of a capacitor is determined by the dielectric material's intrinsic breakdown strength Ebd and thickness d:
For example, polypropylene films exhibit Ebd ≈ 650 kV/mm, allowing a 10 µm film to block 6.5 kV. However, real-world derating (typically 50-80% of theoretical limits) is necessary due to imperfections and aging effects.
Parasitic inductance and equivalent series resistance (ESR) become critical at high dV/dt. The self-resonant frequency fres of a capacitor is given by:
where L includes both internal inductance and external lead contributions.
Inductor Design for High Voltage
High-voltage inductors face unique challenges in insulation and core selection. The voltage gradient across winding layers must remain below the insulation system's partial discharge inception voltage (PDIV). The turn-to-turn voltage Vtt is:
Litz wire is often employed to mitigate skin and proximity effects at high frequencies, with the optimal strand diameter ds scaling as:
where δ is the skin depth and ρ is the conductor resistivity.
Energy Storage Considerations
The energy density comparison between capacitors and inductors reveals fundamental tradeoffs. For a capacitor:
whereas an inductor stores energy as:
High-voltage capacitors typically achieve 0.1-5 J/cm³, while inductors can reach 10-100 J/cm³ in optimized designs. However, inductor energy extraction is limited by L(dI/dt)2 losses during switching.
Transient Response and Ringing
LC circuits in high-voltage applications exhibit underdamped oscillations when:
These oscillations generate voltage overshoots that can exceed twice the DC bus voltage. Snubber networks using series RC circuits are commonly employed to dampen these transients, with the optimal snubber resistance Rsnub approximating the characteristic impedance:
Practical Implementation Challenges
Creepage and clearance distances must adhere to IEC 60664-1 standards. For example, 10 kV operation in pollution degree 2 requires ≥80 mm air clearance and ≥25 mm creepage distance along surfaces. Corona discharge becomes significant above 2-3 kV/mm in air, necessitating:
- Rounded electrode geometries to minimize field enhancement
- Dielectric coatings with high electron affinity (e.g., alumina-filled epoxy)
- Partial discharge testing at 1.5-2× operating voltage
Thermal management is equally critical, with the volumetric loss density q in capacitors being:
where tanδ is the loss tangent of the dielectric material.
4.2 Capacitors and Inductors in High Voltage Circuits
Capacitor Selection and Voltage Stress
In high-voltage circuits, capacitors must withstand significant electric fields without dielectric breakdown. The voltage rating of a capacitor is determined by the dielectric material's intrinsic breakdown strength Ebd and thickness d:
For example, polypropylene films exhibit Ebd ≈ 650 kV/mm, allowing a 10 µm film to block 6.5 kV. However, real-world derating (typically 50-80% of theoretical limits) is necessary due to imperfections and aging effects.
Parasitic inductance and equivalent series resistance (ESR) become critical at high dV/dt. The self-resonant frequency fres of a capacitor is given by:
where L includes both internal inductance and external lead contributions.
Inductor Design for High Voltage
High-voltage inductors face unique challenges in insulation and core selection. The voltage gradient across winding layers must remain below the insulation system's partial discharge inception voltage (PDIV). The turn-to-turn voltage Vtt is:
Litz wire is often employed to mitigate skin and proximity effects at high frequencies, with the optimal strand diameter ds scaling as:
where δ is the skin depth and ρ is the conductor resistivity.
Energy Storage Considerations
The energy density comparison between capacitors and inductors reveals fundamental tradeoffs. For a capacitor:
whereas an inductor stores energy as:
High-voltage capacitors typically achieve 0.1-5 J/cm³, while inductors can reach 10-100 J/cm³ in optimized designs. However, inductor energy extraction is limited by L(dI/dt)2 losses during switching.
Transient Response and Ringing
LC circuits in high-voltage applications exhibit underdamped oscillations when:
These oscillations generate voltage overshoots that can exceed twice the DC bus voltage. Snubber networks using series RC circuits are commonly employed to dampen these transients, with the optimal snubber resistance Rsnub approximating the characteristic impedance:
Practical Implementation Challenges
Creepage and clearance distances must adhere to IEC 60664-1 standards. For example, 10 kV operation in pollution degree 2 requires ≥80 mm air clearance and ≥25 mm creepage distance along surfaces. Corona discharge becomes significant above 2-3 kV/mm in air, necessitating:
- Rounded electrode geometries to minimize field enhancement
- Dielectric coatings with high electron affinity (e.g., alumina-filled epoxy)
- Partial discharge testing at 1.5-2× operating voltage
Thermal management is equally critical, with the volumetric loss density q in capacitors being:
where tanδ is the loss tangent of the dielectric material.
4.3 Switching and Control in High Voltage Systems
Switching Dynamics in High Voltage Circuits
High voltage switching introduces unique challenges due to the rapid changes in electric fields and the potential for parasitic oscillations. The transient behavior during switching is governed by the interaction between stray capacitances (Cstray) and inductances (Lstray), forming an RLC network. The voltage overshoot (Vovershoot) during turn-off can be derived from the damping factor (ζ) of the system:
where R is the circuit resistance. Critical damping (ζ = 1) is often targeted to minimize oscillations while maintaining fast switching.
Solid-State Switching Devices
Modern high voltage systems predominantly use insulated gate bipolar transistors (IGBTs) and silicon carbide (SiC) MOSFETs due to their superior voltage blocking capabilities and switching speeds. Key parameters include:
- Breakdown voltage (VBR): Typically 1.2-6.5 kV for IGBTs, up to 10 kV for SiC devices
- Switching losses (Esw): Proportional to V2 and dependent on gate drive characteristics
- di/dt and dv/dt limitations: Often constrained by package parasitics and thermal considerations
Gate Drive Considerations
Proper gate drive design is critical for reliable switching. The gate charge (Qg) required to switch a device can be calculated as:
where Ciss is the input capacitance and Vgs the gate-source voltage. Practical implementations often use:
- Active Miller clamp circuits to prevent parasitic turn-on
- Galvanic isolation (optocouplers or transformers) for high-side switches
- Negative voltage turn-off (-5 to -15 V) for noise immunity
Snubber Circuits
RC snubbers are commonly employed to suppress voltage spikes. The optimal snubber resistance (Rsnub) and capacitance (Csnub) can be approximated by:
where I0 is the switched current, tf the fall time, and Vpeak the allowable overshoot voltage.
Control Strategies
Advanced control techniques for high voltage systems include:
- Soft switching: Zero-voltage switching (ZVS) or zero-current switching (ZCS) to reduce losses
- Active voltage balancing: For series-connected switches in multilevel converters
- Predictive control: Model-based approaches to anticipate switching transients
Practical Implementation Challenges
Real-world high voltage switching systems must account for:
- Partial discharge inception voltage in insulation systems
- Electromagnetic interference (EMI) generation and mitigation
- Thermal management of switching losses
- Creepage and clearance requirements for PCB layout
4.3 Switching and Control in High Voltage Systems
Switching Dynamics in High Voltage Circuits
High voltage switching introduces unique challenges due to the rapid changes in electric fields and the potential for parasitic oscillations. The transient behavior during switching is governed by the interaction between stray capacitances (Cstray) and inductances (Lstray), forming an RLC network. The voltage overshoot (Vovershoot) during turn-off can be derived from the damping factor (ζ) of the system:
where R is the circuit resistance. Critical damping (ζ = 1) is often targeted to minimize oscillations while maintaining fast switching.
Solid-State Switching Devices
Modern high voltage systems predominantly use insulated gate bipolar transistors (IGBTs) and silicon carbide (SiC) MOSFETs due to their superior voltage blocking capabilities and switching speeds. Key parameters include:
- Breakdown voltage (VBR): Typically 1.2-6.5 kV for IGBTs, up to 10 kV for SiC devices
- Switching losses (Esw): Proportional to V2 and dependent on gate drive characteristics
- di/dt and dv/dt limitations: Often constrained by package parasitics and thermal considerations
Gate Drive Considerations
Proper gate drive design is critical for reliable switching. The gate charge (Qg) required to switch a device can be calculated as:
where Ciss is the input capacitance and Vgs the gate-source voltage. Practical implementations often use:
- Active Miller clamp circuits to prevent parasitic turn-on
- Galvanic isolation (optocouplers or transformers) for high-side switches
- Negative voltage turn-off (-5 to -15 V) for noise immunity
Snubber Circuits
RC snubbers are commonly employed to suppress voltage spikes. The optimal snubber resistance (Rsnub) and capacitance (Csnub) can be approximated by:
where I0 is the switched current, tf the fall time, and Vpeak the allowable overshoot voltage.
Control Strategies
Advanced control techniques for high voltage systems include:
- Soft switching: Zero-voltage switching (ZVS) or zero-current switching (ZCS) to reduce losses
- Active voltage balancing: For series-connected switches in multilevel converters
- Predictive control: Model-based approaches to anticipate switching transients
Practical Implementation Challenges
Real-world high voltage switching systems must account for:
- Partial discharge inception voltage in insulation systems
- Electromagnetic interference (EMI) generation and mitigation
- Thermal management of switching losses
- Creepage and clearance requirements for PCB layout
5. Heat Dissipation in High Voltage Systems
5.1 Heat Dissipation in High Voltage Systems
Thermal Challenges in High Voltage Components
High voltage systems inherently generate significant heat due to resistive losses, dielectric losses, and corona discharge. The power dissipation P in a resistive element follows Joule's first law:
where I is the current and R is the resistance. At high voltages, even small leakage currents can produce substantial heat due to the squared current dependence. Dielectric losses in insulating materials contribute additional heat generation governed by:
where f is frequency, εr'' is the loss factor, E is the electric field strength, and V is the volume of dielectric material.
Heat Transfer Mechanisms
Effective thermal management requires understanding three primary heat transfer mechanisms:
- Conduction: Governed by Fourier's law: q = -k∇T, where k is thermal conductivity
- Convection: Described by Newton's law of cooling: q = hA(Ts - T∞)
- Radiation: Follows Stefan-Boltzmann law: P = εσA(Ts4 - T∞4)
In high voltage systems, conduction typically dominates for internal component cooling, while convection and radiation become critical at external surfaces.
Thermal Design Considerations
Key parameters for thermal design include:
- Maximum junction temperatures for semiconductors (typically 125-150°C)
- Dielectric material temperature limits
- Thermal expansion coefficients of materials
- Coolant properties (for liquid-cooled systems)
The thermal resistance network approach is essential for analyzing heat flow:
where Rth,JC is junction-to-case, Rth,CS is case-to-sink, and Rth,SA is sink-to-ambient thermal resistance.
Practical Cooling Solutions
Effective cooling strategies for high voltage systems include:
- Forced air cooling: Using fans with optimized ducting for HV components
- Liquid cooling: Particularly for high power density systems (>100 W/cm²)
- Heat pipes: Effective for localized hot spots in compact designs
- Phase change materials: For transient thermal management
In transformer design, the thermal time constant τ becomes critical:
where m is mass, cp is specific heat capacity, h is heat transfer coefficient, and A is surface area.
Material Selection
Advanced materials play a crucial role in HV thermal management:
- Aluminum nitride (AlN) substrates with k ≈ 180 W/m·K
- Diamond composites for extreme heat flux applications
- Graphene-enhanced thermal interface materials
- High thermal conductivity ceramics for insulating heat spreaders
The effectiveness of thermal interface materials (TIMs) is quantified by their thermal impedance:
where t is thickness, k is conductivity, A is area, and Rc is contact resistance.
5.1 Heat Dissipation in High Voltage Systems
Thermal Challenges in High Voltage Components
High voltage systems inherently generate significant heat due to resistive losses, dielectric losses, and corona discharge. The power dissipation P in a resistive element follows Joule's first law:
where I is the current and R is the resistance. At high voltages, even small leakage currents can produce substantial heat due to the squared current dependence. Dielectric losses in insulating materials contribute additional heat generation governed by:
where f is frequency, εr'' is the loss factor, E is the electric field strength, and V is the volume of dielectric material.
Heat Transfer Mechanisms
Effective thermal management requires understanding three primary heat transfer mechanisms:
- Conduction: Governed by Fourier's law: q = -k∇T, where k is thermal conductivity
- Convection: Described by Newton's law of cooling: q = hA(Ts - T∞)
- Radiation: Follows Stefan-Boltzmann law: P = εσA(Ts4 - T∞4)
In high voltage systems, conduction typically dominates for internal component cooling, while convection and radiation become critical at external surfaces.
Thermal Design Considerations
Key parameters for thermal design include:
- Maximum junction temperatures for semiconductors (typically 125-150°C)
- Dielectric material temperature limits
- Thermal expansion coefficients of materials
- Coolant properties (for liquid-cooled systems)
The thermal resistance network approach is essential for analyzing heat flow:
where Rth,JC is junction-to-case, Rth,CS is case-to-sink, and Rth,SA is sink-to-ambient thermal resistance.
Practical Cooling Solutions
Effective cooling strategies for high voltage systems include:
- Forced air cooling: Using fans with optimized ducting for HV components
- Liquid cooling: Particularly for high power density systems (>100 W/cm²)
- Heat pipes: Effective for localized hot spots in compact designs
- Phase change materials: For transient thermal management
In transformer design, the thermal time constant τ becomes critical:
where m is mass, cp is specific heat capacity, h is heat transfer coefficient, and A is surface area.
Material Selection
Advanced materials play a crucial role in HV thermal management:
- Aluminum nitride (AlN) substrates with k ≈ 180 W/m·K
- Diamond composites for extreme heat flux applications
- Graphene-enhanced thermal interface materials
- High thermal conductivity ceramics for insulating heat spreaders
The effectiveness of thermal interface materials (TIMs) is quantified by their thermal impedance:
where t is thickness, k is conductivity, A is area, and Rc is contact resistance.
5.2 Effects of Humidity and Contaminants
Humidity and surface contaminants significantly influence high-voltage insulation performance by altering dielectric strength, leakage currents, and partial discharge behavior. The presence of moisture or conductive particles on insulating surfaces can lead to premature breakdown, tracking, or flashover, even at voltages well below the designed withstand levels.
Mechanisms of Humidity-Induced Breakdown
Water molecules adsorbed on insulator surfaces form conductive paths through ionic dissociation. The resulting surface conductivity σs follows an exponential relationship with relative humidity (RH):
where σ0 represents the base conductivity of the clean, dry material and α is a material-specific humidity coefficient. For glass-reinforced epoxy, typical values are σ0 = 10-14 S and α = 0.08 per %RH.
Contaminant Deposition and Tracking
Airborne particulates (salt, dust, industrial pollutants) accumulate on surfaces, creating non-uniform conductivity. When combined with moisture, these contaminants enable leakage currents that follow:
where the integral covers the contaminated surface area S under electric field E(x,y). Localized heating from current concentration causes thermal decomposition of the insulator, forming carbonized tracks that progressively reduce surface resistance.
Tracking Resistance Standards
The comparative tracking index (CTI) quantifies material resistance under standardized contaminant conditions (IEC 60112). Materials are classified as:
- CTI ≥ 600: High resistance (PTFE, ceramic)
- 400 ≤ CTI < 600: Medium resistance (silicone rubber)
- CTI < 400: Low resistance (many polymers)
Partial Discharge in Humid Environments
Moisture absorption increases dielectric permittivity εr while decreasing breakdown strength. The modified Paschen's law for humid air becomes:
where f(RH) is a humidity correction factor typically ranging from 0.7 (100% RH) to 1.0 (dry air). This reduction enables partial discharge inception at lower voltages, with discharge magnitude scaling with absolute humidity.
Design Mitigation Strategies
Effective countermeasures include:
- Creepage extension: Increasing surface path length per IEC 60664-1
- Hydrophobic coatings: Silicone or fluoropolymer treatments
- Periodic washing: For outdoor insulators in polluted areas
- Corona shields: To prevent localized moisture ionization
For critical applications, accelerated aging tests combining humidity cycling (IEC 60068-2-30) with contaminant exposure (IEC 60507) verify long-term performance.
5.2 Effects of Humidity and Contaminants
Humidity and surface contaminants significantly influence high-voltage insulation performance by altering dielectric strength, leakage currents, and partial discharge behavior. The presence of moisture or conductive particles on insulating surfaces can lead to premature breakdown, tracking, or flashover, even at voltages well below the designed withstand levels.
Mechanisms of Humidity-Induced Breakdown
Water molecules adsorbed on insulator surfaces form conductive paths through ionic dissociation. The resulting surface conductivity σs follows an exponential relationship with relative humidity (RH):
where σ0 represents the base conductivity of the clean, dry material and α is a material-specific humidity coefficient. For glass-reinforced epoxy, typical values are σ0 = 10-14 S and α = 0.08 per %RH.
Contaminant Deposition and Tracking
Airborne particulates (salt, dust, industrial pollutants) accumulate on surfaces, creating non-uniform conductivity. When combined with moisture, these contaminants enable leakage currents that follow:
where the integral covers the contaminated surface area S under electric field E(x,y). Localized heating from current concentration causes thermal decomposition of the insulator, forming carbonized tracks that progressively reduce surface resistance.
Tracking Resistance Standards
The comparative tracking index (CTI) quantifies material resistance under standardized contaminant conditions (IEC 60112). Materials are classified as:
- CTI ≥ 600: High resistance (PTFE, ceramic)
- 400 ≤ CTI < 600: Medium resistance (silicone rubber)
- CTI < 400: Low resistance (many polymers)
Partial Discharge in Humid Environments
Moisture absorption increases dielectric permittivity εr while decreasing breakdown strength. The modified Paschen's law for humid air becomes:
where f(RH) is a humidity correction factor typically ranging from 0.7 (100% RH) to 1.0 (dry air). This reduction enables partial discharge inception at lower voltages, with discharge magnitude scaling with absolute humidity.
Design Mitigation Strategies
Effective countermeasures include:
- Creepage extension: Increasing surface path length per IEC 60664-1
- Hydrophobic coatings: Silicone or fluoropolymer treatments
- Periodic washing: For outdoor insulators in polluted areas
- Corona shields: To prevent localized moisture ionization
For critical applications, accelerated aging tests combining humidity cycling (IEC 60068-2-30) with contaminant exposure (IEC 60507) verify long-term performance.
5.3 Design Strategies for Harsh Environments
Material Selection for Dielectric and Structural Integrity
High-voltage systems in harsh environments demand materials with exceptional dielectric strength, thermal stability, and resistance to chemical degradation. For insulating components, cross-linked polyethylene (XLPE) and polytetrafluoroethylene (PTFE) exhibit superior performance in high-temperature and chemically aggressive settings. The dielectric strength Ed of these materials must exceed the maximum electric field Emax by a safety factor ks:
where Emax is derived from the peak operating voltage Vpeak and the minimum insulation thickness d:
Thermal Management Under Extreme Conditions
Thermal runaway in high-voltage components accelerates under elevated ambient temperatures. The power dissipation Pd in a resistive element must account for convective, conductive, and radiative heat transfer:
where h is the convection coefficient, A the surface area, Tj and Ta the junction and ambient temperatures, σ the Stefan-Boltzmann constant, ϵ the emissivity, and Rth the thermal resistance.
Hermetic Sealing and Contamination Mitigation
In environments with particulate or gaseous contaminants, hermetic sealing using Kovar-glass feedthroughs or ceramic-to-metal brazing prevents partial discharge inception. The Paschen curve governs the breakdown voltage Vb as a function of pressure-distance product pd:
where A and B are gas-dependent constants, and γse is the secondary electron emission coefficient.
Mechanical Vibration and Shock Resistance
High-voltage components in aerospace or industrial settings must withstand random vibration spectra per MIL-STD-810. The natural frequency fn of a cantilevered busbar or insulator should avoid resonance with the excitation spectrum:
where E is Young's modulus, I the moment of inertia, m the mass, and L the unsupported length.
Corrosion Protection for Conductive Elements
Silver-plated copper conductors in sulfur-rich environments form non-conductive Ag2S. The corrosion rate follows Arrhenius kinetics:
where δ is the corrosion layer thickness, A the pre-exponential factor, Ea the activation energy, R the gas constant, and T the absolute temperature. Gold or nickel plating provides superior protection where cost permits.
5.3 Design Strategies for Harsh Environments
Material Selection for Dielectric and Structural Integrity
High-voltage systems in harsh environments demand materials with exceptional dielectric strength, thermal stability, and resistance to chemical degradation. For insulating components, cross-linked polyethylene (XLPE) and polytetrafluoroethylene (PTFE) exhibit superior performance in high-temperature and chemically aggressive settings. The dielectric strength Ed of these materials must exceed the maximum electric field Emax by a safety factor ks:
where Emax is derived from the peak operating voltage Vpeak and the minimum insulation thickness d:
Thermal Management Under Extreme Conditions
Thermal runaway in high-voltage components accelerates under elevated ambient temperatures. The power dissipation Pd in a resistive element must account for convective, conductive, and radiative heat transfer:
where h is the convection coefficient, A the surface area, Tj and Ta the junction and ambient temperatures, σ the Stefan-Boltzmann constant, ϵ the emissivity, and Rth the thermal resistance.
Hermetic Sealing and Contamination Mitigation
In environments with particulate or gaseous contaminants, hermetic sealing using Kovar-glass feedthroughs or ceramic-to-metal brazing prevents partial discharge inception. The Paschen curve governs the breakdown voltage Vb as a function of pressure-distance product pd:
where A and B are gas-dependent constants, and γse is the secondary electron emission coefficient.
Mechanical Vibration and Shock Resistance
High-voltage components in aerospace or industrial settings must withstand random vibration spectra per MIL-STD-810. The natural frequency fn of a cantilevered busbar or insulator should avoid resonance with the excitation spectrum:
where E is Young's modulus, I the moment of inertia, m the mass, and L the unsupported length.
Corrosion Protection for Conductive Elements
Silver-plated copper conductors in sulfur-rich environments form non-conductive Ag2S. The corrosion rate follows Arrhenius kinetics:
where δ is the corrosion layer thickness, A the pre-exponential factor, Ea the activation energy, R the gas constant, and T the absolute temperature. Gold or nickel plating provides superior protection where cost permits.
6. High Voltage Testing Methods
6.1 High Voltage Testing Methods
Dielectric Withstand Testing
Dielectric withstand testing, commonly referred to as hipot testing, evaluates the insulation integrity of high-voltage components by applying a voltage significantly higher than the operational rating. The test voltage, typically 1.5 to 3 times the rated voltage, is sustained for a predefined duration (e.g., 1 minute for IEC standards). Failure modes include insulation breakdown, partial discharge, or excessive leakage current.
where k is the safety factor (1.5–3) and Vrated is the nominal operating voltage.
Partial Discharge Measurement
Partial discharge (PD) occurs in localized insulation defects under high electric stress. PD testing involves:
- Calibrated coupling capacitors to detect high-frequency pulses.
- Ultra-high-frequency (UHF) sensors for gas-insulated systems.
- Phase-resolved partial discharge analysis (PRPDA) to identify discharge patterns.
The apparent charge Q is quantified in picoCoulombs (pC):
where C is the coupling capacitance and ΔV is the measured voltage pulse.
Impulse Voltage Testing
Lightning and switching surges are simulated using standardized impulse waveforms:
- 1.2/50 μs lightning impulse (front time/tail time).
- 250/2500 μs switching impulse.
The waveform is generated via Marx generators or capacitive multipliers. The peak voltage Vp and time parameters must comply with IEC 60060-1.
Ramp Testing
Ramp testing gradually increases voltage until breakdown occurs, providing the dielectric strength limit. The ramp rate (e.g., 1 kV/s) must be controlled to avoid thermal artifacts. The breakdown voltage Vbd follows the Weibull distribution for statistical analysis:
where α is the scale parameter and β is the shape parameter.
Corona Detection
Corona discharge in air is identified using:
- UV cameras for visual detection of ionization.
- Radio interference voltage (RIV) meters for RF emissions.
- Acoustic sensors for ultrasonic signatures.
The inception voltage Vi follows Peek’s law for coaxial geometries:
where E0 is the critical electric field, r is the inner conductor radius, and R is the outer radius.
6.2 Diagnostic Techniques for Insulation Failure
Partial Discharge (PD) Measurement
Partial discharge (PD) is a localized dielectric breakdown in high-voltage insulation systems, often preceding catastrophic failure. PD events generate high-frequency current pulses, electromagnetic emissions, and acoustic signals, which can be detected using specialized sensors. The apparent charge Q of a PD event is quantified as:
where i(t) is the transient current pulse. Calibrated high-frequency current transformers (HFCTs) or capacitive couplers are typically used for measurement. Phase-resolved partial discharge (PRPD) patterns further help identify defect types (e.g., voids, surface discharges) by correlating PD magnitude with the AC cycle phase angle.
Dielectric Response Analysis
Dielectric spectroscopy measures the complex permittivity ε*(ω) of insulation materials as a function of frequency:
Degraded insulation exhibits increased dielectric losses (ε'') and frequency-dependent dispersion shifts. Polarization/depolarization current (PDC) and frequency domain spectroscopy (FDS) are two common techniques. PDC analyzes time-domain currents after DC voltage application, while FDS sweeps frequencies from 1 mHz to 1 kHz.
Tan Delta (Dissipation Factor) Testing
The dissipation factor tan δ measures insulation quality by comparing resistive and capacitive current components under AC stress:
A rising tan δ indicates moisture ingress, aging, or contamination. Schering bridges or modern digital analyzers apply test voltages (typically 2–10 kV) at power frequencies (50/60 Hz) or very low frequencies (VLF, 0.1 Hz). IEEE Std 286-2000 provides standardized testing procedures.
Insulation Resistance (IR) and Polarization Index (PI)
IR testing applies DC voltage (500 V to 15 kV) to measure leakage current through insulation. The polarization index (PI) is the ratio of 10-minute to 1-minute resistance values:
Healthy insulation exhibits PI > 2.0, while values < 1.0 indicate severe degradation. Temperature correction is critical, as resistivity follows Arrhenius behavior:
Thermal Imaging and Thermography
Infrared cameras detect localized heating from partial discharges or increased dielectric losses. Temperature rises ΔT in defective regions follow Joule heating principles:
where Rth is thermal resistance. FLIR systems with < 50 mK thermal sensitivity are commonly used for substation inspections. Differential analysis compares phases under balanced loads to identify anomalies.
Ultrasonic and Acoustic Emission (AE) Detection
PD events generate pressure waves in the 20–200 kHz range. Piezoelectric sensors (e.g., resonant or wideband) convert these to electrical signals. The acoustic intensity I at distance r from a PD source is:
where α is the attenuation coefficient. Time-of-flight analysis locates defects in transformers or GIS systems. AE hit rates and amplitude distributions correlate with insulation degradation severity.
Gas Chromatography (DGA) for Oil-Immersed Systems
Dissolved gas analysis (DGA) detects fault gases (H2, CH4, C2H2, etc.) in transformer oil. Key ratios (e.g., Duval Triangle) identify thermal or electrical faults. The Rogers ratio method evaluates:
Gas generation rates follow Arrhenius kinetics, with activation energies varying by fault type (e.g., 80 kJ/mol for cellulose degradation).
6.3 Reliability and Lifetime Assessment
Failure Mechanisms in High-Voltage Components
The dominant failure modes in high-voltage systems stem from dielectric breakdown, partial discharge, and thermal degradation. The Weibull distribution effectively models time-to-failure statistics for insulation systems:
where η is the characteristic lifetime (63.2% failure probability) and β is the shape parameter indicating failure mode dispersion. For corona discharge, β typically ranges 0.7–1.3, while for thermal aging, values of 3–4 are common.
Accelerated Life Testing Methodology
High-voltage components undergo accelerated aging tests using the inverse power law for voltage stress:
where n is the voltage endurance coefficient (6–12 for polymer films, 9–15 for oil-paper systems). The Arrhenius equation governs thermal acceleration:
Typical activation energies (Ea) range 0.8–1.2 eV for insulation materials.
Partial Discharge Analysis
Partial discharge (PD) patterns reveal insulation defects through phase-resolved measurements. The apparent charge q and discharge energy W are critical metrics:
Modern PD mapping uses φ-q-n patterns (phase-angle vs. charge magnitude vs. pulse count) with machine learning classifiers achieving >90% defect identification accuracy.
Condition Monitoring Techniques
- Dissolved gas analysis (DGA): Key gas ratios (CH4/H2, C2H2/C2H4) predict transformer faults
- Tan δ monitoring: Dielectric loss tangent exceeding 0.5% indicates moisture ingress
- Ultra-wideband sensors: Detect PD pulses with <1 ns rise time for GIS systems
Lifetime Prediction Models
The Eyring-Weibull combined stress model integrates multiple degradation factors:
where RH is relative humidity and γ the moisture coefficient (0.03–0.07 for epoxy composites). Bayesian updating refines predictions using field monitoring data.
7. Key Textbooks and Research Papers
7.1 Key Textbooks and Research Papers
- High Voltage Engineering Fundamentals — 3.5.2 Voltage dividers and passive rectifier circuits 113 3.5.3 Active peak-reading circuits 117 3.5.4 High-voltage capacitors for measuring circuits 118 3.6 Voltage dividing systems and impulse voltage measurements 129 3.6.1 Generalized voltage generation and measuring circuit 129 3.6.2 Demands upon transfer characteristics of the measuring ...
- PDF Design Guide: Designing and Building High Voltage Power Supplies ... - DTIC — 5.3.2.1 Mechanical Design Considerations 30 5.3.2.2 Electrical Design Considerations 30 3.3.2.3 Low Voltage 33 ... The U.S. Air Force has emphasized the use of new development electronic components and designs, materials technmologies, manufacturing, and test techniques ... Volume 11 is a high voltage design guide for airborne equipment, which ...
- High Voltage Engineering Fundamentals Technology Applications by ... — Academia.edu is a platform for academics to share research papers. High Voltage Engineering Fundamentals Technology Applications by Kuchler, Andreas ... High-voltage engineering covers the application, the useful use and proper working of high voltages and high fields. ... design and construction of impulse generators 66 2.4 Control systems 74 ...
- GaN Transistors for Efficient Power Conversion - Wiley Online Library — 3.11.3 Higher‐Voltage Configurations 64 3.12 Summary 64 Reference s 65 4 69Layout Considerations for GaN Transistor Circuits 4.1 Introduc tion 69 4.2 Minimizing Parasitic Inductance 69 4.3 Conventional Power‐Loop Designs 72 4.3.1 Lateral Power‐Loop Design 72 4.3.2 Vertical Power‐Loop Design 73 4.4 Optimizing the Power Loop 74
- PDF Space engineering - High voltage engineering and design handbook — Space engineering - High voltage engineering and design handbook Ingénierie spatiale - Manuel d'ingénierie et de conception haute tension Raumfahrttechnik - Handbuch für Hochspannungstechnik und Design This Technical Report was approved by CEN on 14 June 2021. It has been drawn up by the Technical Committee CEN/CLC/JTC 5.
- Selected Papers from 2018 IEEE International Conference on High Voltage ... — Data of the high voltage direct current (HVDC) test line considered in the calculations. ... successfully in a high-voltage apparatus quality supervision and inspection test center as a preliminary research test. The key information is summarized in Table 5, and all recorded waveforms of the breaking current and the TRV are shown in Figures 9 ...
- PDF Fundamentals of Electronic Circuit Design - University of Cambridge — 7 1 The Basics 1.1 Voltage and Current Voltage is the difference in electrical potential between two points in space. It is a measure of the amount of energy gained or lost by moving a unit of positive charge from one point to another, as shown in Figure 1.1. Voltage is measured in units of Joules per Coulomb, known as a Volt (V).
- High Voltage Engineering - SpringerLink — The time T 1 is the front time, defined as 1.67 times the time T AB, which is the measured time between points A (30%) and B (90%) of the maximum value of test voltage \(\hat{u}\).The front time of a standard lightning impulse is 1.2 μs ± 30%. The time T 2 is the time to half value, which means the difference between the two 50% points of the voltage curve.
- Practical Considerations for the Design and Implementation of High ... — This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed.
- PDF ABSTRACT - research.ece.ncsu.edu — Design Considerations of High Voltage and High Frequency 3 Phase Transformer for Solid State Transformer Application by Chun-kit Leung A thesis submitted to the Graduate Faculty of North Carolina State University in partial fulfillment of the requirements for the Degree of Master of Science Electrical Engineering Raleigh, North Carolina 2010
7.2 Industry Standards and Guidelines
- PDF Design Guide: Designing and Building High Voltage Power Supplies ... - DTIC — 5.3.2.2 Electrical Design Considerations 30 3.3.2.3 Low Voltage 33 5.3.2.4 High Voltage 34 5.3.2.5 Future Requirements 38 5.3.2.6 Techniques To Obtain 39 Higher Output Power Density 5.3.2.7 Nonstandard Parts for Higher 47 Output Power Density 5.4 Input Power 47 5.4.1 Input Power Standard 48
- High Voltage Design and Installations Master Class — Shall contribute to ensuring electromagnetic compatibility among electrical and electronic apparatus of the high-voltage system in accordance with Standards; Where high- and low-voltage earthing systems exist in proximity to each other and do not form a global earthing system, part of the EPR from the HV system can be applied on the LV system ...
- DOE-HDBK-1092-2013 July 2013 DOE HANDBOOK DOE-HDBK-1092-2004 ELECTRICAL ... — NOT MEASUREMENT SENSITIVE. DOE HANDBOOK . ELECTRICAL SAFETY . DOE-HDBK-1092-2013 July 2013 Superseding DOE-HDBK-1092-2004 December 2004 . U.S. Department of Energy AREA SAFT
- Design and Manufacturing Standard for Electrical Harnesses — 4.4 High voltage design and construction- Circuits carrying potentials in excess of 200Vac, rms, or 300Vdc through critical pressure environments should be terminated in single contact high voltage connectors.If the design requires that high voltage circuits be terminated in multicontact connectors, contacts should be selected which are the most distant from ground potentials.
- PDF ITER Electrical Design Handbook Codes & Standards — ITR-20-005 ITER Electrical Design Handbook Codes & Standards Joel Hourtoule [email protected] 16 July 2020
- PDF Electrical Design Handbook — defines a set of standard voltages for use in low voltage and high voltage AC electricity supply systems. The definition of voltage levels is as follows: IEC voltage range AC DC defining risk . Extra-low voltage
- Guideline for planning of HVDC systems - iTeh Standards — IEC TR 63179-1:2020 (E) provides guidelines for the selection of a high-voltage directive current (HVDC) system with line-commutated converters (LCC), hereafter referred to as HVDC system, for the purposes of HVDC system planning. It covers the guidelines on the requirements for integrating HVDC systems in AC power networks, selection of rated voltage and power, overloads, circuit ...
- PDF AVR040: EMC Design Considerations - Microchip Technology — AVR040: EMC Design Considerations APPLICATION NOTE Scope ... electronic appliances is increasing every year. • Electronic circuits are becoming more and more sensitive ... body. VS is a high-voltage power supply, and R C the series resistance of this power supply. When the
- PDF A Guide to United States Electrical and Electronic Equipment ... - NIST — This guide addresses electrical and electronic consumer products, including those that will . In addition, it includes electrical and electronic products used in the workplace as well as electrical and electronic medical devices. The scope does not include vehicles or components of vehicles, electric or electronic toys, or recycling ...
- PDF IEEE Guide for the Design and Installation of Cable Systems in Substations — The existence of an IEEE Standard does not imply that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE Standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to change brought about through developments in the
7.3 Online Resources and Tutorials
- PDF Design Guide: Designing and Building High Voltage Power Supplies ... - DTIC — 5.3.2.2 Electrical Design Considerations 30 3.3.2.3 Low Voltage 33 5.3.2.4 High Voltage 34 ... The U.S. Air Force has emphasized the use of new development electronic components and designs, materials technmologies, manufacturing, and test techniques ... Volume 11 is a high voltage design guide for airborne equipment, which is applicable to ...
- PDF High Voltage Engineering - Helsinki — 3.5.2 Voltage dividers and passive rectifier circuits 113 3.5.3 Active peak-reading circuits 117 3.5.4 High-voltage capacitors for measuring circuits 118 3.6 Voltage dividing systems and impulse voltage measurements 129 3.6.1 Generalized voltage generation and measuring circuit 129 3.6.2 Demands upon transfer characteristics of the measuring ...
- PDF The Art of Electronics — 1.2 Voltage, current, and resistance 1 1.2.1 Voltage and current 1 1.2.2 Relationship between voltage and current: resistors 3 1.2.3 Voltage dividers 7 1.2.4 Voltage sources and current sources 8 1.2.5 Thevenin equivalent circuit 9´ 1.2.6 Small-signal resistance 12 1.2.7 An example: "It's too hot!" 13 1.3 Signals 13 1.3.1 Sinusoidal ...
- PDF Chapter 7 High-Voltage and Power Transistors - Springer — analyzed, followed by a discussion of DEMOS and LDMOS design considerations andcharacteristics.High-voltageand high-current effects are then described,includ-ing quasi-saturation(QS),body current, on-state breakdown, and safe operating area (SOA). The chapter concludes with selected high-voltage device applications. 7.1 Introduction
- PDF High Voltage Design Guide for Airborne Equipment - DTIC — HIGH VOLTAGE DESIGN GUIDE FOR A.IRBORNE EQUIPMENT 26 September 1975-June 1976 6. PERFORMING ORG. REPORT NUMBER I. AUTHOR(a) 8. ... 4.1.1 Design Considerations 112 4.1.2 High Voltage Cable 115 4.1.3 High Voltage Connectors 118 4.2 Capacitors 119 4.2.1 Construction and Processing 119 4.2°2 Dielectrics 120 ...
- PDF A compendium of articles from Electronic Design Q1 L BEST OF — A trusted industry resource for more than 50 years, the Penton Electronics Group is the electronic design engineer's source for design ideas and solutions, new technology information and engineering essentials. Individual brands in the group include Electronic DesignMicrowaves & RF, and Power Electronics.
- PDF Fundamentals of Electronic Circuit Design - University of Cambridge — Fundamentals of Electronic Circuit Design Outline Part I - Fundamental Principles 1 The Basics 1.1 Voltage and Current 1.2 Resistance and Power 1.3 Sources of Electrical Energy 1.4 Ground 1.5 Electrical Signals 1.6 Electronic Circuits as Linear Systems 2 Fundamental Components: Resistors, capacitors, and Inductors 2.1 Resistor 2.2 Capacitors
- PDF High-voltage-tolerant I/O Design for Usb 2.0-compliant Systems — ages. The design problems associated with over-voltage conditions are important be-cause it directly affects the lifetime of the product. In this work, we identify design challenges in the presence of over-voltage condi-tions and derive design guidelines for end-user systems taking a USB 2.0-compliant I/O as a test vehicle.
- PDF AVR040: EMC Design Considerations - Microchip Technology — AVR040: EMC Design Considerations APPLICATION NOTE Scope ... From 1995, Europe introduced regulations on immunity for all electronic products, known as the EMC directive. The purpose of this directive is: ... body. VS is a high-voltage power supply, and R C the series resistance of this power supply. When the
- PDF Digital Designer's Guide to Linear Voltage Regulators and Thermal ... — SLVA118 4 Digital Designer's Guide to Linear Voltage Regulators and Thermal Management PQ is derived by multiplying the input voltage by the quiescent current of the regulator. Thermally, PQ is usually insignificant, as it is orders of magnitude smaller than the output current. For example, the TPS789xx series of 100 mA (or 0.1 A) low dropout regulators (LDO)