Fast acting power supply protection


Posted on May 25, 2012

When using a regulated power supply to reduce a supply voltage, there is always the danger that component failure in the power supply might lead to a severe overvoltage condition across the load. To cope with overvoltage situations, the circuit is designed to protect the load under overyoltage conditions. Component values given are for a 20 V supply with regulated output at 12 V. The zener diode can be changed according to whatever voltage is to be the maximum


Fast acting power supply protection
Click here to download the full size of the above Circuit.

If the voltage at the regulator output rises to 13 V or above, the zener diode breaks down and triggers the thyristor which shorts out the supply line and blows the main fuse.




Leave Comment

characters left:

Related Circuits

  • New Circuits

    .

     


    Popular Circuits

    Audio isolation transformer
    Diode Cmos Stabilizer
    ?» The stepper motor driver Creative Works of Tom McGuire
    Metal detector 8
    Broadband sine wave voltage controlled oscillator circuit diagram LF356N
    Fire Alarm schematic design