The LM1812 is a complete ultrasonic transceiver integrated circuit designed for various pulse-echo ranging applications. The chip functions by transmitting a burst of oscillations through a transducer, which is then used to listen for a return echo. If an echo of sufficient amplitude is detected, the LM1812 outputs a pulse approximately the same width as the original burst. The time taken for the echo to return is inversely proportional to the distance of the reflecting object.
Echos can be received immediately after the initial burst is transmitted, however, the transducer experiences ringing. During transmission, the transducer is excited with several hundred volts peak-to-peak and operates in a loudspeaker mode. When the LM1812 ceases transmission and begins reception, the transducer continues to vibrate or ring, despite the cessation of excitation. Acting as a microphone, the transducer generates an AC signal initially matching the amplitude of the transmit pulse. This signal diminishes over time, governed by the transducer's damping factor. As long as detectable ringing persists, the LM1812's detector remains active, which masks any return echoes.
The LM1812 integrated circuit is designed for ultrasonic ranging applications, utilizing a transducer that serves dual functions—transmitting and receiving ultrasonic signals. The operation begins with the chip generating a high-voltage burst to excite the transducer, producing ultrasonic waves that propagate through the environment. Upon encountering an object, these waves reflect back towards the transducer.
The chip's ability to detect echoes relies on the amplitude of the returning signal. When the echo is received, the LM1812 generates an output pulse that corresponds in width to the original transmission. This output pulse is critical for distance measurement, as the time delay between transmission and reception is used to calculate the distance to the reflecting object.
However, the transducer's ringing effect poses a challenge. After the transmission phase, the transducer continues to vibrate due to the energy stored in its mechanical structure. This ringing can interfere with the detection of echoes by producing a residual signal that can mask the return echoes. The LM1812 is designed to manage this by holding the detector active until the ringing dissipates to a level below the detection threshold, thereby ensuring that valid echoes can be distinguished from the transducer's residual vibrations.
The performance of the LM1812 is influenced by several factors, including the transducer's characteristics, such as its frequency response and damping factor. Proper selection of the transducer is essential to optimize the system's range and accuracy. Additionally, the circuit's design must consider the operating environment, as factors like temperature and humidity can affect ultrasonic wave propagation and transducer performance.
In summary, the LM1812 ultrasonic transceiver provides a robust solution for distance measurement applications through its dual-function transducer and sophisticated echo detection capabilities, while also addressing the challenges posed by transducer ringing.The LM1812 is a complete ultrasonic transceiver on a chip designed for use in a variety of pulse-echo ranging applications. The chip operates by transmitting a burst of oscillations with a transducer, then using the same transducer to listen for a return echo.
Ifan echo of sufficient amplitude is received, the LM1812 detector puts out a pulse of approximately the same width as the original burst. The closer the reflecting object, the earlier the return echo. Echos could be received immediately after the initial burst was transmitted, except for the fact that the transducer rings. When transmitting, the transducer is excited with several hundred volts peak to peak, and it operates in a loudspeaker mode.
Then, when the LM1812 stops transmitting and begins to receive, the transducer continues to vibrate or ring, even though excitation has stopped. The transducer acts as a microphone and produces an ac signal initially the same amplitude as the transmit pulse.
This signal dies away as is governed by the transducer"s damping factor, but as long as detectable ringing remains, the LM1812"s detector will be held on, masking any return echos.
This ultrasonic transmit/receive circuit operates at 40 kHz. Control resistor R5 adjusts the frequency for optimal performance with the transducers used.
The ultrasonic transmit/receive circuit designed to operate at a frequency of 40 kHz is essential for applications in distance...