Coke Thermal infrared detection circuit OPA111


Posted on Mar 28, 2007

An application focus infrared heat is radiated by an object while the object of infrared non-contact temperature measurement, since the detection of the measured signal is very


Coke Thermal infrared detection circuit OPA111
Click here to download the full size of the above Circuit.

weak, thus requiring the use of coke thermal infrared sensor sensitivity must be very high, the noise is very small; the same of the amplifier circuit is also very demanding, with the general operational amplifier is unable to meet the requirements. OPA111 structure into focus infrared thermal measurement circuit as shown in FIG. The general structure of the circuit as an operational amplifier, except that the feedback resistor is very large (requires gain is very large); signal pin signal lead and copper traces printed circuit board must make the mask processing. Because the gain of the amplifier is large, if not shielded, then external noise can cause interference.




Leave Comment

characters left:

New Circuits

.

 


Popular Circuits

Voltage-to-current converters
DIY FSK RFID Reader using Arduino
Studio of Bill Ooms Computerized Ornamental Lathe
A contact-less digital tachometer based on optical sensors
circuit How to find currents of all nodes using superposition theorem
water level controller circuit diagram
Light Gate With Counter Using 555 And 4033
Breaker control signal circuit manually



Top