Isolated Fuse Fail Indicator


Posted on Feb 5, 2014

This circuit uses standard components and shows a method of indicating the fuse status of mains powered equipment while providing electrical isolation from the mains supply. A standard miniature low power mains transformer (e. g. with an output of around 6 V at 1. 5 VA) is used as a sense` transformer with its primary winding (230 V) connected acros


Isolated Fuse Fail Indicator
Click here to download the full size of the above Circuit.

s the equipment`s input fuse so that when the fuse blows, mains voltage is applied to the transformer and a 6 V ac output voltage appears at the secondary winding. The 1N4148 diode rectifies this voltage and the LED lights to indicate that the fuse has failed. The rectified voltage is now connected to an RC low-passlter formed by the 10 k resistor and 100 nF capacitor. The resulting positive signal can now be used as an input to an A/D converter or as a digital input to a microcontroller (make sure that the signal level is within the microcontroller input voltage level specification). The 1 M resistor is used to discharge the capacitor if the input impedance of the connected equipment is very high. As long as the fuse remains intact it will short out the primary winding of the sense` transformer so that its secondary output is zero.




Leave Comment

characters left:

Related Circuits

  • New Circuits

    .

     


    Popular Circuits

    Pierce-gate oscillator
    Invisible infrared pulsed laser
    LPG Gas Leakage Sensor Alarm
    3 channel audio splitter
    Geomagnetic field detectors
    TDA2030 200 watt amp low cost audio power amplifier
    Harald Bode Klangumwandler
    1N4001 Diodes
    Schumann Resonance Converter
    Bedini SSG
    A decorative quartz voice packet clock circuit



    Top