Isolated Fuse Fail Indicator


Posted on Feb 5, 2014

This circuit uses standard components and shows a method of indicating the fuse status of mains powered equipment while providing electrical isolation from the mains supply. A standard miniature low power mains transformer (e. g. with an output of around 6 V at 1. 5 VA) is used as a sense` transformer with its primary winding (230 V) connected acros


Isolated Fuse Fail Indicator
Click here to download the full size of the above Circuit.

s the equipment`s input fuse so that when the fuse blows, mains voltage is applied to the transformer and a 6 V ac output voltage appears at the secondary winding. The 1N4148 diode rectifies this voltage and the LED lights to indicate that the fuse has failed. The rectified voltage is now connected to an RC low-passlter formed by the 10 k resistor and 100 nF capacitor. The resulting positive signal can now be used as an input to an A/D converter or as a digital input to a microcontroller (make sure that the signal level is within the microcontroller input voltage level specification). The 1 M resistor is used to discharge the capacitor if the input impedance of the connected equipment is very high. As long as the fuse remains intact it will short out the primary winding of the sense` transformer so that its secondary output is zero.




Leave Comment

characters left:

Related Circuits

  • New Circuits

    .

     


    Popular Circuits

    Lead Acid Battery Charger II
    Digital-ad-capacitance-meter
    Ultrasonic-receiver
    Variable-Frequency Audio Bp Filter Circuit
    Axe Grinder Electric Guitar Effect
    Automatic Water Tank FillerCircuit Circuit
    two stage fm transmitter bug more tank circuits
    12v power supply circuit
    Kodiak Military History Fire Control Telephones
    Assembling The Speed Controller
    Remote Doorbell Controller
    Controlling Motor Starting
    Clock Circuit Design
    Sequential timing control circuit diagram



    Top