linear regulator


Posted on Dec 9, 2012

Intended for extreme temperature, radiation-hardened environments, this linear supply is capable of supplying 28 Vdc at 125 A from an ac-driven power unit. In operation, power supply output voltage is sensed by the voltage divider consisting of R24 to R28 and fed to one input of a discrete differential amplifier composed of Q13 through Q16. The other input of the amplifier is connected to a radiation-hardened zener diode, Dl.


linear regulator
Click here to download the full size of the above Circuit.

Local feedback using R21 and Cl produces gain to phase shift that are independent of individual component parameters, which provides stable operation into the required loads.