SHD102 single station to pump water controlled auto-voltage starting circuit a closed
Not rated
25,105
SHD102 single station to pump water controlled auto-voltage starting a closed
Autotransformer voltage starting, with an adjustable starting time of 30-60 seconds. It includes the SDJ electrode liquid level sensor of HJ-13 type, a pump control system box of HKD-21B type, 1MK level modules adopted by HKG-1SG type, 2MK start module of Hoc-21 type, and SY run sensor of HQC-1 type.
The described system utilizes an autotransformer to manage voltage levels during the starting phase of connected equipment. The adjustable starting time, ranging from 30 to 60 seconds, allows for customization based on specific operational requirements, ensuring a smooth ramp-up of voltage to prevent inrush current that could potentially damage sensitive components.
The SDJ electrode liquid level sensor of HJ-13 type serves as a crucial component in monitoring liquid levels, providing real-time feedback to the control system. This sensor operates on the principle of conductivity, where the presence of liquid completes an electrical circuit, thus signaling the control system to engage or disengage the pump as necessary.
The pump control system box, identified as HKD-21B type, acts as the central hub for managing the operation of the pump based on inputs from the liquid level sensor. It is designed to handle the control signals and power requirements for the pump, ensuring efficient operation and protection against dry running conditions.
The integration of 1MK level modules of HKG-1SG type enhances the system's capability to monitor multiple levels or conditions, providing flexibility and scalability. Similarly, the 2MK start module of Hoc-21 type is utilized to manage the starting sequence of the pump, ensuring that it initiates only when all safety and operational conditions are met.
Finally, the SY run sensor of HQC-1 type is implemented to monitor the operational status of the pump during its run phase, providing feedback to the control system for real-time adjustments and ensuring optimal performance throughout its operational cycle. This comprehensive setup allows for efficient management of liquid levels and pump operation, contributing to the overall reliability and effectiveness of the system. Autotransformer voltage starting, starting time 30-60s adjustable. Figure, SDJ electrode liquid level sensor HJ-13-type, pump control system box with HKD-21B type, 1MK level mo dules adopted by HKG-1SG type, 2MK start module Hoc-21 type, SY run sensor HQC- l type.
Most recent cars are equipped with a significant amount of electronics, including ABS brake systems, engine control with injection calculators, airbag activation, and various comfort functions. One such function, often overlooked due to its commonality, is the automatic activation...
Amplifier circuit featuring a MOSFET output stage, serving as an alternative to the output stage that utilizes bipolar transistors. Advantages of the MOSFET amplifier include ease of operation, the ability to handle hundreds of watts with straightforward parallel configurations,...
This circuit is designed to support nine independent telephones using a single telephone line pair, allowing for operation at nine different locations. It includes a bidirectional telephone line simulator that does not require actual telephone lines, enabling the coupling,...
This circuit generates a siren sound when switch S1 is pressed. The sound frequency increases as capacitor C1 charges, and when switch S1 is released, the frequency decreases as capacitor C1 discharges.
The circuit operates on a simple principle of...
The first circuit energizes the relay when the light rises above the preset level. The second circuit energizes the relay when the light falls below the preset level. The two circuits are practically identical. The only difference between them...
Various threads on ringer circuits have been observed, showcasing multiple variants, particularly concerning the types of transformers utilized, such as air core and step-down transformers. One notable circuit is the 12V-to-120V configuration, which employs a joule ringer that utilizes...