Check For Op-Amp Dc Offset Shift Circuit


Posted on Dec 29, 2012

The dc values of op-amp offsets can`t always be taken for granted when delivering ac outputs. No device is ever exactly symmetrical for maximum positive slew rate versus maximum negative slew rate. Consequently, there is always some range of output slew rates in which the device used limits in one direction more severely than in the other. What results in rectification of the ac signal and an apparent shift of the dc offset. This test circuit can check for the shift phenomenon. The accompanying table and graph illustrate the results obtained for four devices, all of different types.


Check For Op-Amp Dc Offset Shift Circuit
Click here to download the full size of the above Circuit.

As frequency and slew rate are increased, the effect can be either relatively abrupt (LF412CN and NE55532N) or relatively gradual (LF358J and TL0820P).